Double Containment Piping

Where LibertyCES specs Double Containment Piping
Chemical compatibility
Technical guides for Double Containment Piping
Frequently Asked Questions
What industries use Double Containment Piping?
LibertyCES has documented Double Containment Piping specified across 1 sector application, including Direct Lithium Extraction (DLE).
What is a real-world application of Double Containment Piping in Direct Lithium Extraction (DLE)?
Duo-Pro is Asahi's own recommended system for DLE brine/acid handling per the ASAHI FOR DLE source; named chemistries are sodium hypochlorite, chlorine dioxide and acids (lithium-rich brine eluents). The 30-day EPA containment figure is the quotable design basis on a DLE permitting conversation. — examples include Asahi/America Duo-Pro double containment in PP, PVDF or ECTFE (1x3 through 16x20, 150psi + drainage ratings, outer pipe designed to meet the EPA standard of at least 30 days of containment, simultaneous or staggered butt fusion, leak-detection cable installable on 2x6 and larger), Asahi/America PAL-AT cable-based leak detection, LiquidWatch II electronic leak detection. This is well-documented in LibertyCES's field data.
Is Double Containment Piping compatible with Metal Plating & Photographic Process Solutions?
The strongest plating-bath evidence in the corpus, and real field data rather than a compatibility table. Four UTC Goodrich Cleveland installations from 2013 are documented: 30-37% chromic acid with 35% sulfuric acid; a 7-9% sodium cyanide + 2% sodium hydroxide + 3% cadmium oxide + 6% sodium carbonate mixture; 25% nickel sulfate; and contaminated groundwater remediation. That cyanide/cadmium/caustic/carbonate mixture is an actual plating-bath waste stream, confirming Chem Prolok double-wall containment for the cyanide-bearing waste itself rather than only the treatment instrumentation. Broader pattern: of the 26 documented installations at least 9 explicitly replaced failed or leaking PVC or CPVC. Materials to confirm: Advanced PE PE445584C / PAS 1075, PP, PVDF, ECTFE (Duo-Pro), Simultaneous butt fusion only for double-wall (primary + secondary fused in one operation), Explicit vendor installation rule: threaded joints should not be allowed. Specific chemicals include chromic acid 30-37%, sulfuric acid 35%, sodium cyanide 7-9%, sodium hydroxide 2%, cadmium oxide 3%, sodium carbonate 6%, nickel sulfate 25%, spent solvent drain, process waste.
Send LibertyCES the process data, not a part number
Fluid, chemistry, concentration, temperature, flow, pressure, line size, and current equipment — that's what a real spec review needs to start.